Definition of Cryogenic Needle Valve
A cryogenic needle valve refers to a needle valve applicable to fluids such as liquefied gases, including LO2 (liquid oxygen), LN2 (liquid nitrogen), LAr (liquid argon), LNG (liquefied natural gas), LC2H4 (liquid ethylene), ethylene, liquid hydrogen, liquid ammonia, liquid propane, and liquefied petroleum gas. Imported cryogenic needle instrument valves share the same structural form as globe valves, feature an extended stem design, and can withstand a low temperature of -196℃.
Technical Parameters of Cryogenic Needle Valve
Product Name: Cryogenic Needle Valve
Nominal Diameter: 1/8"~2"; custom specifications available
Actuation Method: Manual
Connection Type: Flange, welded, threaded, and other types of joints available
Nominal Pressure: 10000Psi; Maximum Pressure ≤10000Psi
Applicable Temperature: -196℃~+70℃; Maximum Temperature ≤425℃
Applicable Media: LO2 (liquid oxygen), LN2 (liquid nitrogen), LAr (liquid argon), LNG (liquefied natural gas), LC2H4 (liquid ethylene), ethylene, liquid hydrogen, liquid ammonia, liquid propane, etc.
Product Weight: 1KG~15KG
Valve Body Material: SS304, SS316, SS316L
Structure Type: Globe type
Applicable Occasions: Ethylene plants, LNG facilities, LNG storage tanks, receiving terminals and satellite stations, air separation equipment, petrochemical tail gas separation equipment, cryogenic carbon dioxide storage tanks and tank trucks, pressure swing adsorption oxygen generation, etc.
Test Pressure: 1.5 times the maximum working pressure
Product Characteristics of Cryogenic Needle Valve
Lowest temperature application: The metal material maintains the mechanical properties required for working conditions at low temperatures.
Possesses impact toughness, relative elongation, and structural stability.
Features good wear resistance under low-temperature and oil-free lubrication conditions.
Has good corrosion resistance.
When using welded connections, the weldability of the material also needs to be considered.